LAS S WS noir / black
Safety connector for tower construction with screw connection for leads from 0.5 mm² to 1.5 mm², outer diameter of lead max. 4.2 mm. Plug 4 mm with caged spring, rigid socket 4 mm, 1000 V-system. Simple assembly by "Click-System".
Technical data
connection
screw terminal
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT II
rated current(consider derating curve)
24 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
2,34 € vat included 21%
SEB 2620 F6.3 rouge / rouge
Safety press-in socket, 4 mm diameter, contact-protected, with 6.3 x 0.8 tab connector complying with DIN 46 244, gold-plated brass. For rapid installation into switchpanels with wall thicknesses between 1-10 mm.Installation hole: Ø12.2 ±0.1 mmEntry chamfer: 0.5 x 45°
Technical data
connection
flat connector 6.3 x 0.8 mm
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT III
rated current(consider derating curve)
32 A
material socket
brass, gold plated
housing material
PA
temperature range acc. To IEC61010(1)
-40 °C to +80 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
2,53 € vat included 21%
SEB 2620 F6.3 jaune / yellow
Safety press-in socket, 4 mm diameter, contact-protected, with 6.3 x 0.8 tab connector complying with DIN 46 244, gold-plated brass. For rapid installation into switchpanels with wall thicknesses between 1-10 mm.Installation hole: Ø12.2 ±0.1 mmEntry chamfer: 0.5 x 45°
Technical data
connection
flat connector 6.3 x 0.8 mm
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT III
rated current(consider derating curve)
32 A
material socket
brass, gold plated
housing material
PA
temperature range acc. To IEC61010(1)
-40 °C to +80 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
2,53 € vat included 21%
SEB 2620 F6.3 vert / vert
Safety press-in socket, 4 mm diameter, contact-protected, with 6.3 x 0.8 tab connector complying with DIN 46 244, gold-plated brass. For rapid installation into switchpanels with wall thicknesses between 1-10 mm.Installation hole: Ø12.2 ±0.1 mmEntry chamfer: 0.5 x 45°
Technical data
connection
flat connector 6.3 x 0.8 mm
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT III
rated current(consider derating curve)
32 A
material socket
brass, gold plated
housing material
PA
temperature range acc. To IEC61010(1)
-40 °C to +80 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
2,53 € vat included 21%
SEP 2620 F6.3 noir / black
Safety press-in socket, 4 mm diameter, contact-protected, with 6.3 x 0.8 tab connector complying with DIN 46 244, gold-plated brass. For rapid installation into switchpanels with wall thicknesses between 1-10 mm.Installation hole: Ø12.2 ±0.1 mmEntry chamfer: 0.5 x 45°
Technical data
connection
flat connector 6.3 x 0.8 mm
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT III
rated current(consider derating curve)
32 A
material socket
brass, gold plated
housing material
PA
temperature range acc. To IEC61010(1)
-40 °C to +80 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
1,95 € vat included 21%
AK 2 B 2540 I rouille / rouge
Contact-protected, high-strength, wide-opening alligator clip.Clamping range up to 30mm bolt diameter.Solid wire clip, U-shaped and fine wire section.Nickel-plated brass connecting socket, pluggable with 4mm safety measuring leads.
Technical data
connection
unsprung socket 4 mm
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT II
rated current(consider derating curve)
32 A
material socket
brass, nickel plated
housing material
PP
temperature range acc. To IEC61010(1)
-30 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
HB
clamping range
30 mm
4,49 € vat included 21%
AK 2 B 2540 I jaune / yellow
Contact-protected, high-strength, wide-opening alligator clip.Clamping range up to 30mm bolt diameter.Solid wire clip, U-shaped and fine wire section.Nickel-plated brass connecting socket, pluggable with 4mm safety measuring leads.
Technical data
connection
unsprung socket 4 mm
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT II
rated current(consider derating curve)
32 A
material socket
brass, nickel plated
housing material
PP
temperature range acc. To IEC61010(1)
-30 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
HB
clamping range
30 mm
4,49 € vat included 21%
LAS 30 rot / rouge
Laminated, shatter-proof plug with caged spring and tapering sleeve providing protection against kinking. Soldered connections up to 1.5mm², cable diameters up to 4.2mm. Nickel-plated brass contact, nickel-plated copper beryllium contact spring.
Technical data
connection
solder connection
rated voltage
30 VAC / 60 VDC
measurement cat. acc. to IEC 61010
O (2)
rated current(consider derating curve)
32 A
material socket
contact pin: brasscontact spring: copper - beryllium
housing material
PVC-P
temperature range acc. To IEC61010(1)
-25 °C to +70 °C
1,63 € vat included 21%
MVL 2/100 rot / rouge
Injection-moulded measuring lead, at either end 2 mm diameter nickel-plated brass connector and 2 mm diameter socket with contact spring, for tower constructions. Highly flexible stranded lead 0.5 mm², grip and lead shatter-proof.
Technical data
rated voltage
30 VAC / 60 VDC
measurement cat. acc. to IEC 61010
O (2)
rated current(consider derating curve)
6 A
material socket
contact pin: brasscontact spring: copper - beryllium
housing material
PP
temperature range acc. To IEC61010(1)
-40 °C to +60 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
HB
cable length
100 cm
conductor size
0,5 mm²
cable material
PVC
6,34 € vat included 21%
MICRO-KLEPS rouille / rouge
Miniature clamp-type test probe with rotating grip jaws (SMD technology). The insulated shaft can be bent up to 35º. Suitable for very thin wires and densely packed contact points (1.27 mm IC spacing pitch). Connects with MKL... and MAL...
Technical data
connection
2 x unsprung pin Ø 0.64 mm
rated voltage
30 VAC / 60 VDC
measurement cat. acc. to IEC 61010
O (2)
rated current(consider derating curve)
2 A
material plug
brass, gold plated
housing material
PBT
temperature range acc. To IEC61010(1)
-25 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
HB
clamp type
rotating grip jaws, tin plated
clamping range
1,6 mm
5,40 € vat included 21%
KLEPS 1600 rouge / rouge
Safety clamp-type test probe with rotating grip jaws and flexible shaft. Wires and pins up to a maximum diameter of 3 mm can be clamped thanks to the special form of the grip jaws. Ø 2 mm sockets-connection of brass gold-plated.
Technical data
connection
unsprung socket 2 mm
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT II
rated current(consider derating curve)
3 A
material socket
brass, gold plated
housing material
PA
temperature range acc. To IEC61010(1)
-25 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
clamp type
rotating grip jaws, tin plated
clamping range
3 mm
7,97 € vat included 21%
MVL S WS 200/1 Noir / black
Safety measuring lead, at either end 2 mm diameter safety connector / safety socket with onward connection capability. Gold-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, shatter-proof grip sleeve and lead. In accordance to IEC 61010 Standard. Built in indicator for easy identification of insulation damages.
Technical data
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT III
rated current(consider derating curve)
10 A
material plug
brass, gold plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable
10,60 € vat included 21%