MLS GG 100/1 noir / black
Safety measuring lead, at either end 4 mm diameter safety connector with straight outlet. Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, shatter-proof grip sleeve and lead. Color indicator for the recognition of damage to the insulation. In accordance to IEC 61010 standard.
Technical data
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT III
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
100 cm
conductor size
6,75 € vat included 21%
MLS GG 100/1 rot / rouge
Safety measuring lead, at either end 4 mm diameter safety connector with straight outlet. Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, shatter-proof grip sleeve and lead. Color indicator for the recognition of damage to the insulation. In accordance to IEC 61010 standard.
Technical data
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT III
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
100 cm
conductor size
1 mm�
6,75 € vat included 21%
MLS GG 100/1 bleu / blue
Safety measuring lead, at either end 4 mm diameter safety connector with straight outlet. Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, shatter-proof grip sleeve and lead. Color indicator for the recognition of damage to the insulation. In accordance to IEC 61010 standard.
Technical data
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT III
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
100 cm
conductor size
1 m
6,75 € vat included 21%
MLS WS 100/2,5 jaune / yellow
Safety measuring lead to IEC 61010 standard, at either end 4 mm diameter safety connector with onward connection capability (4mm socket). Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, shatter-proof grip sleeve and lead. Built in color indicator for easy indentification of insulation damages.
Technical data
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT II
rated current(consider derating curve)
32 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
100 c
8,18 € vat included 21%
MLS WS 200/2,5 gruen / vert
Safety measuring lead to IEC 61010 standard, at either end 4 mm diameter safety connector with onward connection capability (4mm socket). Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, shatter-proof grip sleeve and lead. Built in color indicator for easy indentification of insulation damages.
Technical data
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT II
rated current(consider derating curve)
32 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
200 c
9,23 € vat included 21%
MLN SIL 25/1 noir / black
Measuring lead, at either end 4 mm diameter plug with caged spring and 4 mm diameter socket for tower construction. Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, grip and lead shatter-proof. Built in colour indicator for easy identification of insulation damages.
Technical data
rated voltage
30 VAC / 60 VDC
measurement cat. acc. to IEC 61010
O (2)
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
25 cm
conductor size
1 mm²
5,18 € vat included 21%
MLN SIL 100/1 jaune / yellow
Measuring lead, at either end 4 mm diameter plug with caged spring and 4 mm diameter socket for tower construction. Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, grip and lead shatter-proof. Built in colour indicator for easy identification of insulation damages.
Technical data
rated voltage
30 VAC / 60 VDC
measurement cat. acc. to IEC 61010
O (2)
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
100 cm
conductor size
1 mm²
6,20 € vat included 21%
MLN SIL 200/1 rot / rouge
Measuring lead, at either end 4 mm diameter plug with caged spring and 4 mm diameter socket for tower construction. Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, grip and lead shatter-proof. Built in colour indicator for easy identification of insulation damages.
Technical data
rated voltage
30 VAC / 60 VDC
measurement cat. acc. to IEC 61010
O (2)
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
200 cm
conductor size
1 mm²
cab
7,89 € vat included 21%
MLS WS 100/1 noir / black
Safety measuring lead to IEC 61010 standard, at either end 4 mm diameter safety connector with onward connection capability (4mm socket). Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, shatter-proof grip sleeve and lead. Built in color indicator for easy indentification of insulation damages.
Technical data
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT II
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
100 c
7,56 € vat included 21%
MLS WS 100/1 rot / rouge
Safety measuring lead to IEC 61010 standard, at either end 4 mm diameter safety connector with onward connection capability (4mm socket). Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, shatter-proof grip sleeve and lead. Built in color indicator for easy indentification of insulation damages.
Technical data
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT II
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
100 cm
co
7,56 € vat included 21%
KUN S noir / black
Safety coupling with screw connection for leads from 0.5mm² to 1.5mm², outer diameter of lead max. 4,2mmConnectable with plugs 4mm and safety plugs 4mm1000V-system, IEC 61010.Simple assembly by "Click-System".
Technical data
connection
screw terminal
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT III
rated current(consider derating curve)
24 A
material socket
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
3,04 € vat included 21%
KUN S rouge
Safety coupling with screw connection for leads from 0.5mm² to 1.5mm², outer diameter of lead max. 4,2mmConnectable with plugs 4mm and safety plugs 4mm1000V-system, IEC 61010.Simple assembly by "Click-System".
Technical data
connection
screw terminal
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT III
rated current(consider derating curve)
24 A
material socket
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
3,04 € vat included 21%