Liste des produits de la marque SKS Hirschmann
SKS Hirschmann
Il y a 148 produits.
MLN 150/1 bleu / blue
Measuring lead, at either end 4 mm diameter plug with caged spring and 4 mm diameter socket for tower construction. Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, grip and lead shatter-proof. Built in colour indicator for easy identification of insulation damages.
Technical data
rated voltage
30 VAC / 60 VDC
measurement cat. acc. to IEC 61010
O (2)
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
150 cm
conductor size
1 mm²
cable
4,68 € vat included 21%
MLN 200/1 vert / green
Measuring lead, at either end 4 mm diameter plug with caged spring and 4 mm diameter socket for tower construction. Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, grip and lead shatter-proof. Built in colour indicator for easy identification of insulation damages.
Technical data
rated voltage
30 VAC / 60 VDC
measurement cat. acc. to IEC 61010
O (2)
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
200 cm
conductor size
1 mm²
cab
5,25 € vat included 21%
MLS WS 50/1 rot / rouge
Safety measuring lead to IEC 61010 standard, at either end 4 mm diameter safety connector with onward connection capability (4mm socket). Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, shatter-proof grip sleeve and lead. Built in color indicator for easy indentification of insulation damages.
Technical data
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT II
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to 70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
50 cm
condu
6,05 € vat included 21%
MLS GG 100/1 noir / black
Safety measuring lead, at either end 4 mm diameter safety connector with straight outlet. Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, shatter-proof grip sleeve and lead. Color indicator for the recognition of damage to the insulation. In accordance to IEC 61010 standard.
Technical data
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT III
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
100 cm
conductor size
5,75 € vat included 21%
MLS GG 100/1 rot / rouge
Safety measuring lead, at either end 4 mm diameter safety connector with straight outlet. Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, shatter-proof grip sleeve and lead. Color indicator for the recognition of damage to the insulation. In accordance to IEC 61010 standard.
Technical data
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT III
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
100 cm
conductor size
1 mm�
5,75 € vat included 21%
MLS GG 100/1 bleu / blue
Safety measuring lead, at either end 4 mm diameter safety connector with straight outlet. Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, shatter-proof grip sleeve and lead. Color indicator for the recognition of damage to the insulation. In accordance to IEC 61010 standard.
Technical data
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT III
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
100 cm
conductor size
1 m
5,75 € vat included 21%
MLS WS 100/2,5 jaune / yellow
Safety measuring lead to IEC 61010 standard, at either end 4 mm diameter safety connector with onward connection capability (4mm socket). Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, shatter-proof grip sleeve and lead. Built in color indicator for easy indentification of insulation damages.
Technical data
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT II
rated current(consider derating curve)
32 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
100 c
6,97 € vat included 21%
MLS WS 200/2,5 gruen / vert
Safety measuring lead to IEC 61010 standard, at either end 4 mm diameter safety connector with onward connection capability (4mm socket). Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, shatter-proof grip sleeve and lead. Built in color indicator for easy indentification of insulation damages.
Technical data
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT II
rated current(consider derating curve)
32 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
200 c
7,86 € vat included 21%
MLN SIL 25/1 noir / black
Measuring lead, at either end 4 mm diameter plug with caged spring and 4 mm diameter socket for tower construction. Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, grip and lead shatter-proof. Built in colour indicator for easy identification of insulation damages.
Technical data
rated voltage
30 VAC / 60 VDC
measurement cat. acc. to IEC 61010
O (2)
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
25 cm
conductor size
1 mm²
4,41 € vat included 21%
MLN SIL 100/1 jaune / yellow
Measuring lead, at either end 4 mm diameter plug with caged spring and 4 mm diameter socket for tower construction. Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, grip and lead shatter-proof. Built in colour indicator for easy identification of insulation damages.
Technical data
rated voltage
30 VAC / 60 VDC
measurement cat. acc. to IEC 61010
O (2)
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
100 cm
conductor size
1 mm²
5,27 € vat included 21%
MLN SIL 200/1 rot / rouge
Measuring lead, at either end 4 mm diameter plug with caged spring and 4 mm diameter socket for tower construction. Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, grip and lead shatter-proof. Built in colour indicator for easy identification of insulation damages.
Technical data
rated voltage
30 VAC / 60 VDC
measurement cat. acc. to IEC 61010
O (2)
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
200 cm
conductor size
1 mm²
cab
6,72 € vat included 21%
MLS WS 100/1 noir / black
Safety measuring lead to IEC 61010 standard, at either end 4 mm diameter safety connector with onward connection capability (4mm socket). Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, shatter-proof grip sleeve and lead. Built in color indicator for easy indentification of insulation damages.
Technical data
rated voltage
AC/DC 1000 V
measurement cat. acc. to IEC 61010
CAT II
rated current(consider derating curve)
16 A
material plug
brass, nickel plated
housing material
PA
temperature range acc. To IEC61010(1)
-15 °C to +70 °C
inflammability class acc. to UL 94(only valid for basic material of housing)
V-2
cable length
100 c
6,44 € vat included 21%