1. Summarize

LC frequency convert voltage module LC_F2V is A pulse signal into analog voltage signal to frequency module.Able to 0-1 KHZ frequency conversion of 0-10 v output voltage.Adjusting frequency can change the output voltage.Can be used to interface between PLC and frequency converter conversion, or movement control CARDS and converter interface matching control occasions.

2. Functional characteristics

1 Enter  different frequency, output corresponding voltage
2 Input pulse level is 5 v, 12 v and 24 vall can be input directly, without resistance.The input signal frequency should maintain more than 0.5 seconds.
3 The output voltage can be fine-tuning.By potentiometer to calibrate the relationship between frequency and voltage.
4 Signal input using the light lotus root isolation, guarantee the anti-interference ability.
5If you need matched with PLC, support of NPN. must be ground.
6 If should be matched with the encoder, the encoder constant speed continues to turn more than 0.5 seconds.
7F/V converter module, response time, 0.3 to 0.5 seconds.As a big adjust frequency, need certain response time.

3. Introduce of Hardware and Illustrate

(1)Connection details:
VCC: Working power supply.
GND
The power supply.
F: Input frequency pulse signal.
GND: Input fields.
VOUT: Output voltage levels.
GND: Output.
Module altogether.Connection details:
VCC: Working power supply.
GND, The power supply.
F: Input frequency pulse signal.
GND: Input fields.
VOUT: Output voltage levels.
GND: Output.

(2) Operating Instructions

The working voltage VCC &gnd, not reverse connection, in order to avoid damage to the board and components.
Will pick on F, frequency pulse signal on VOUT is corresponding to the output voltage.
Corresponding relations between input and output:
100 hz = 1 v.
1 KHZ = 10 v.
Module accuracy is 1%, the accuracy is higher when do not apply.
When using corresponding relation if there is a deviation, can adjust potentiometer to calibration.

LC-LM331_V2F